Plain Lab · logbook
Electrical Test and Inspection Log
Sixty circuit test records ruled into six columns, with a place to write the reading your tester showed and no printed pass figure to compare it against.
Specification
- Trim
- 148 × 210 mm · 5.827 × 8.268 in
- Pages
- 100
- Leaves
- 50
- Sheets
- 25
- Signatures
- 5 × 20pp
- Spine
- 5.72 mm
- Paper
- white
- Ruling
- lined
- Ruling pitch
- 7.14 mm · 20.25 pt · 9/32 in
- Rows per page
- 24
Six columns run down sixty pages of log: date, circuit, insulation, continuity, trip time, result. A result of pass or fail without the reading beside it tells nobody how close the circuit actually came to the line.
Twenty-nine lined pages follow, for what a six-column row cannot carry: which circuit kept tripping under load, what changed between one test and the next, a note to check a particular joint again next time round.
No minimum insulation reading and no acceptable trip time is printed anywhere in this log. Those figures sit in the wiring regulation you test against, and that regulation gets revised on its own schedule, one a bound book cannot follow. Write down the number your tester actually showed, and judge it against the rule current on the day you tested.
What is inside
- Log
- 60pp
- Six columns fixed, so two electricians testing the same circuit months apart record it the same way.
- Notes
- 29pp
- Lined, for the fault and repeat-test history a six-column row cannot carry.
- Reference
- 6pp
- Length and temperature conversions computed from definitions, plus emergency numbers checked against two sources each.
- Last leaf
- 1pp
- A pen-test page, printed on purpose, so a real test page does not take the hit.
The film
Page by page
A vertical film from our own bench — this page contacts nobody's server to play it, and downloads nothing until you press play.
Real pages


Made at the Hibrkraft bindery, Bogor · about the maker
Books that sit alongside it
- Calibration LogWorks alongsideshares quality-inspector, record-keeping
- Chemical Store and Disposal LogWorks alongsideshares field-work, record-keeping
- Compressor Service LogbookWorks alongsideshares field-work, record-keeping
- Equipment Inspection BookWorks alongsideshares quality-inspector, record-keeping
- Forklift Pre-Use Inspection BookWorks alongsideshares field-work, quality-inspector, record-keeping
- Lifting Gear RegisterWorks alongsideshares field-work, record-keeping
- Quality Inspection BookWorks alongsideshares quality-inspector, record-keeping
- Waste Transfer LogWorks alongsideshares field-work, record-keeping
Questions
What are the six columns?
Date, Circuit, Insulation, Continuity, Trip time, Result.
How big is it?
A5, 148 x 210 mm, 100 pages, 5.72 mm across the spine.
Is it dated?
No. Start it whenever the first circuit gets tested.
Does it print an acceptable insulation value or trip time?
No, and that is deliberate. Those figures sit in the wiring regulation you test against, they are revised on their own schedule, and a printed book cannot follow a revision. Record the reading your tester actually showed, and check it against the rule current on the day.
What ruling are the notes pages?
Lined, 7.14 mm pitch, 9/32 inch, twenty-four lines to the page.
Who is it for?
Electricians and quality inspectors testing circuits against a wiring regulation, who need the same six facts written down for every circuit.
Indeed it is proverbial that the bad workman never yet had a good tool.